Stycznik mocy I=32A [AC-3] 1Z 0R

  • szt.
  • Rabat: -385,96 zł (40 %)
  • (Rabat brutto: -474,73 zł (40 %))
  • Cena brutto: 712,10 zł / szt. 578,94 zł / szt.
Stycznik mocy I=32A [AC-3] DILM32-10(RDC130)
Program
Product range
  Contactors
Application
  Contactors for Motors
Subrange
  Contactors up to 170 A, 3 pole
Connection technique
  Screw terminals
Rated operational current
   
AC-3
   
380 V 400 V
IeA32
AC-1
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 60 °C
Ith =IeA40
Max. rating for three-phase motors, 50 - 60 Hz
   
AC-3
   
220 V 230 V
PkW10
380 V 400 V
PkW15
660 V 690 V
PkW17
AC-4
   
220 V 230 V
PkW4
380 V 400 V
PkW7
660 V 690 V
PkW10
Contacts
   
N/O = Normally open
  1 N/O
Contact sequence
  
Can be combined with auxiliary contact
  DILM32-XHI..
DILA-XHI(V)..
Voltage AC/DC
  DC operation
Approbationen
Product StandardsIEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.E29096
UL CCNNLDX
CSA File No.012528
CSA Class No.2411-03, 3211-04
NA CertificationUL Listed, CSA certified
Specially designed for NANo
 
General
Standards
  IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
   
AC operated
Operationsx 10610
DC operated
Operationsx 10610
Operating frequency, mechanical
   
AC operated
Operations/h 5000
DC operated
Operations/h 5000
Climatic proofing
  Damp heat, constant to IEC 60068-2-78
Damp heat, cyclic to IEC 60068-2-30
Ambient temperature
 °C 
Open
 °C-25- 60
Enclosed
 °C-25- 40
Storage
 °C-40- 80
Mounting position, AC- and DC operated
  
Mechanical shock resistance (IEC/EN 60068-2-27)
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g10
Auxiliary contacts
   
N/O contact
 g7
N/C contact
 g5
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g6.9
Auxiliary contacts
   
N/O contact
 g5.3
N/C contact
 g3.5
Protection type
  IP00
Protection against direct contact when actuated from front (EN 90274)
  Finger- and back-of-hand proof
Weight
   
AC operated
 kg0.42
DC operated
 kg0.48
Terminal capacity main cable
   
Solid
 mm21 x (0.75 - 16)
2 x (0.75 - 10)
Flexible with ferrule
 mm21 x (0.75 - 16)
2 x (0.75 - 10)
Stranded
 mm21 x 16
Solid or stranded
 AWG18 - 6
Main cable connection screw/bolt
  M5
Tightening torque
 Nm3.2
Terminal capacity control circuit cables
   
Solid
 mm21 x (0.75 - 4)
2 x (0.75 - 4)
Flexible with ferrule
 mm21 x (0.75 - 1.5)
2 x (0.75 - 1.5)
Solid or stranded
 AWG18 - 14
Control circuit cable connection screw/bolt
  M3.5
Tightening torque
 Nm1.2
Tool
   
Main cable
   
Pozidriv screwdriver
 Size2
Standard screwdriver
 mm0.8 x 5.5
1 x 6
Control circuit cables
   
Pozidriv screwdriver
 Size2
Standard screwdriver
 mm0.8 x 5.5
1 x 6
Terminal capacity control circuit cables
   
Solid
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible with ferrule
 mm21 x (0.75 - 1.5)
2 x (0.75 - 1.5)
Solid or stranded
 AWG18 - 14
Tool
   
Stripping length
 mm10
Screwdriver blade width
 mm3.5
Main conducting paths
Rated impulse withstand voltage
UimpV AC8000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV AC690
Safe isolation to VDE 0106 Part 101 and Part 101/A1
   
between coil and contacts
 V AC440
between the contacts
 V AC440
Making capacity (p.f. to IEC/EN 60947)
   
 
Up to 690 VA384
Breaking capacity
   
220/230 V
 A320
380/400 V
 A320
500 V
 A320
660/690 V
 A180
Short-circuit rating
   
Short-circuit protection maximum fuse
   
Type “2” coordination
   
400 V
gG/gL 500 VA 63
690 V
gG/gL 690 VA 35
Type “1” coordination
   
400 V
gG/gL 500 VA 125
690 V
gG/gL 690 VA 63
AC
AC-1 duty
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA45
at 50 °C
Ith =IeA43
at 55 °C
Ith =IeA42
at 60 °C
Ith =IeA40
enclosed
IthA36
Conventional free air thermal current, 1 pole
   
open
IthA100
enclosed
IthA90
AC-3 duty
   
Rated operational current AC-3 open, 50 - 60 Hz, 3 pole
Ie  
220/230 V
IeA32
240 V
IeA32
380/400 V
IeA32
415 V
IeA32
440V
IeA32
500 V
IeA32
660/690 V
IeA18
Motor rating
PkWh 
220/230 V
PkW10
240V
PkW11
380/400 V
PkW15
415 V
PkW19
440 V
PkW20
500 V
PkW23
660/690 V
PkW17
AC-4 duty
   
Rated operational current AC-4 open, 50 - 60 Hz, 3 pole
Ie  
220/230 V
IeA15
240 V
IeA15
380/400 V
IeA15
415 V
IeA15
440 V
IeA15
500 V
IeA15
660/690 V
IeA12
Motor rating
PkWh 
220/230 V
PkW4
240 V
PkW4.5
380/400 V
PkW7
415 V
PkW7.5
440 V
PkW8
500 V
PkW9
660/690 V
PkW10
DC
Rated operational current, open
   
DC-1 operation
   
60 V
IeA40
110 V
IeA40
220 V
IeA40
440 V
IeA2.9
DC-3 operation
   
60 V
IeA40
110 V
IeA40
220 V
IeA25
440 V
IeA0.6
DC-5 operation
   
60 V
IeA40
110 V
IeA40
220 V
IeA10
440 V
IeA0.6
Current heat loss (3 pole)
Current heat loss at Ith
 W12.1
Current heat loss at Ieto AC-3/400 V
 W6.1
Impedance per pole
 mΩ2
Magnet systems
Voltage tolerance
 x Uc 
AC operated
Pick-upx Uc0.8- 1.1
Drop-out voltage AC operated
Drop-outx Uc0.3- 0.6
Notes
  RDC 130 (Umin110 V DC/Umax130 V DC)
Example: Uc= 0.7 x Umin- 1.2 x Umax/ Uc= 0.7 x 110 V - 1.2 x 130 V DC
DC operated
Pick-upx Uc0.7- 1.2
Notes
  at least smoothed two-phase bridge rectifier or three-phase rectifier
DC operated
Drop-outx Uc0.15- 0.6
Power consumption of the coil in a cold state and 1.0 x Uc
   
50 Hz
Pick-upVA52
50 Hz
SealingVA7.1
50 Hz
SealingW2.1
60 Hz
Pick-upVA67
60 Hz
SealingVA8.7
60 Hz
SealingW2.6
50/60 Hz
Pick-upVA62
58
50/60 Hz
SealingVA9.1
6.5
50/60 Hz
SealingW2.5
2
DC operated
Pick-upW12
DC operated
SealingW0.5
Duty factor
 % DF100
Switching times at 100 % Uc(approximate values)
   
Main contacts
   
AC operated
   
Closing delay
 ms16- 22
Opening delay
 ms8- 14
DC operated
 ms 
Closing delay
 ms47
Opening delay
 ms30
Arcing time
 ms10
Lifespan, mechanical; Coil 50/60 Hz
at 50 Hz Mechanical lifespan at 50 Hz approx. 30% lower than under “Technical data, general”
Electromagnetic compatibility (EMC)
Emitted interference
  to EN 60947-1
Interference immunity
  to EN 60947-1
Technical data according to ETIM 4.0
Number of main contacts as N/Os
  3
Rated operation current Ie at AC-1, 400 V
  45
Connection type main circuit
  Screw connection
Rated control voltage Us at AC 60HZ
 V0
Number of auxiliary contacts as N/Os
  1
Rated control voltage Us at AC 50HZ
 V0
Number of auxiliary contacts as N/Cs
  0
Suitable for rail-mounting
  No
Rated control voltage Us at DC
 V130
Voltage type for actuation
  DC
Rated operation current Ie at AC-3, 400 V
 A32
Number of N/Cs as main contact
  0
Motor rating at AC-3, 400 V
 kWh15
Characteristics
1: Overload relay
2: Suppressor
3: Auxiliary contact modules
Projektieren
Squirrel-cage motor
Operating characteristics
Starting:from rest
Stopping:after attaining full running speed
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 1 x rated motor current
Utilization category
100 % AC-3
Typical applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
Fans
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevators
Air conditioning system
General drives in manufacturing and processing machines
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
Dimensions
Contactor with auxiliary contact module
Lateral clearance to earthed parts: 6 mm

Opis pochodzi ze strony www.moeller.net .