Stycznik mocy;AC-3/400V:4kW 3-bieg. DC DILEM-10-G(24VDC)

  • Dodaj recenzję:
  • Kod: 010213
  • Dostępność: Jest  (2 szt.)
  • szt.
  • Cena brutto: 307,75 zł 250,20 zł

Stycznik mocy;AC-3/400V:4kW 3-bieg. DC DILEM-10-G(24VDC)

Program
Product range
    Contactors
Subrange
    DILEM contactors
Application
    Mini Contactors for Motors and Resistive Loads
Description
    With auxiliary contact
Pole
    3 pole
Connection technique
    Screw terminals
Rated operational current
     
AC-3
     
400 V
Ie A 9
AC-1
     
Conventional free air thermal current, 3 pole, 50 - 60 Hz
     
Open
     
at 50 °C
Ith =Ie A 20
enclosed
Ith A 16
Max. rating for three-phase motors, 50 - 60 Hz
     
AC-3
     
220 V 230 V
P kW 2.2
380 V 400 V
P kW 4
660 V 690 V
P kW 4
AC-4
     
220 V 230 V
P kW 1.5
380 V 400 V
P kW 3
660 V 690 V
P kW 3
Contacts
     
N/O = Normally open
    1 N/O
Contact sequence
   
For use with
    …DILEM
…DILE
Actuating voltage
    24 V DC
Voltage AC/DC
    DC operation
Approbationen
Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No. E29096
UL CCN NLDX
CSA File No. 012528
CSA Class No. 3211-04
NA Certification UL Listed, CSA certified
Specially designed for NA No
 
General
Standards
    IEC/EN 60947, VDE 0660, CSA, UL
Maximum operating frequency
  Ops./h  
Mechanical
  Ops./h 9000
Climatic proofing
    Damp heat, constant to IEC 60068-2-78
Damp heat, cyclic to IEC 60068-2-30
Ambient temperature
  °C  
Open
  °C -25- 50
Enclosed
  °C -25- 40
Mounting position
   
As required except vertical with terminals A1/A2 at the bottom
Mounting position
    As required, except vertical with terminals A1/A2 at the bottom
Mechanical shock resistance (IEC/EN 60068-2-27)
     
Half-sinusoidal shock, 10 ms
     
Basic unit without auxiliary contact module
     
Main contacts, make contacts
  g 10
Main contacts Make/break contacts
  g 10/8
Basic unit with auxiliary contact module
     
Main contacts make contact
  g  
Make
  g 10
Auxiliary contacts Make/break contacts
  g 20/20
Protection type
    IP20
Protection against direct contact when actuated from front (EN 90274)
    Finger and back-of­hand proof
Weight
  kg 0.17
Terminal capacity of auxiliary and main contacts
     
Solid
  mm2 1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible with ferrule
  mm2 1 x (0.75 - 1.5)
2 x (0.75 - 1.5)
Solid or stranded
  AWG 18 - 14
Terminal screw
    M3.5
Pozidriv screwdriver
  Size 2
Standard screwdriver
  mm 0.8 x 5.5
1 x 6
Max. tightening torque
  Nm 1.2
Terminal capacity springloaded terminals main and control circuits
     
Solid
  mm2 1 x (1 - 2.5)
2 x (1 - 2.5)
Flexible with ferrule
  mm2 1 x (1 - 2.5)
2 x (1 - 2.5)
Standard screwdriver
  mm 0.6 x 3.5
Main conducting paths
Rated impulse withstand voltage
Uimp V AC 6000
Overvoltage category/pollution degree
    III/3
Rated insulation voltage
Ui V AC 690
Rated operational voltage
Ue V AC 690
Safe isolation to VDE 0106 Part 101 and Part 101/A1
     
between coil and contacts
  V AC 300
between the contacts
  V AC 300
Making capacity (cos ϕ to IEC/EN 60947)
  A 110
Breaking capacity
     
220/230 V
  A 90
380/400 V
  A 90
500 V
  A 64
660/690 V
  A 42
Short-circuit protection maximum fuse
     
Type “2” coordination
gL/gG A 10
Type “1” coordination
gL/gG A 20
AC
AC-1 duty
     
Conventional free air thermal current, 3 pole, 50 - 60 Hz
     
Open
     
at 40 °C
Ith =Ie A 22
at 50 °C
Ith =Ie A 20
at 55 °C
Ith =Ie A 19
enclosed
Ith A 16
Notes
    At maximum permissible ambient air temperature.
Conventional free air thermal current, 1 pole
     
Notes
    At maximum permissible ambient air temperature.
open
Ith A 50
enclosed
Ith A 40
AC-3 duty
     
Rated operational current AC-3 open, 50 - 60 Hz, 3 pole
Ie    
Notes
    At maximum permissible ambient air temperature.
220/230 V
Ie A 9
240 V
Ie A 9
380/400 V
Ie A 9
415 V
Ie A 9
440V
Ie A 9
500 V
Ie A 6.4
660/690 V
Ie A 4.8
Motor rating
P kWh  
220/230 V
P kW 2.2
240V
P kW 2.5
380/400 V
P kW 4
415 V
P kW 4.3
440 V
P kW 4
500 V
P kW 4
660/690 V
P kW 4
AC-4 duty
     
Rated operational current AC-4 open, 50 - 60 Hz, 3 pole
Ie    
Notes
    At maximum permissible ambient air temperature.
220/230 V
Ie A 6.6
240 V
Ie A 6.6
380/400 V
Ie A 6.6
415 V
Ie A 6.6
440 V
Ie A 6.6
500 V
Ie A 5
660/690 V
Ie A 3.4
Motor rating
P kWh  
220/230 V
P kW 1.5
240 V
P kW 1.8
380/400 V
P kW 3
415 V
P kW 3.1
440 V
P kW 3
500 V
P kW 3
660/690 V
P kW 3
DC
Rated operational current, open
Ie    
DC - -1
     
12 V
Ie A 20
24 V
Ie A 20
60 V
Ie A 20
110 V
Ie A 20
220 V
Ie A 20
DC - 3
     
12 V
Ie A 8
24 V
Ie A 8
60 V
Ie A 4
110 V
Ie A 3
DC - 5
     
12 V
Ie A 2.5
24 V
Ie A 2.5
60 V
Ie A 2.5
110 V
Ie A 1.5
220 V
Ie A 0.3
Current heat losses (3- or 4-pole)
     
to Ith
  W 3.5
at Ieto AC-3/400 V
  W 0.7
Magnet systems
Voltage tolerance
  x Uc  
DC operated
Pick-up x Uc 0.8- 1.1
Power consumption
     
DC operation
     
Power consumption Pick-up = Sealing
  VA/W 2.6
Notes
    Smoothed DC voltage or three-phase bridge rectifier
Duty factor
  % DF 100
Switching times at 100 % Uc
     
Make contact
  ms  
Closing delay
  ms  
Closing delay min.
  ms 26
Closing delay max.
  ms 35
Opening delay
  ms  
Opening delay min.
  ms 15
Opening delay max.
  ms 25
Closing delay with top mounting auxiliary contact
  ms max. 70
Reversing contactors
     
Changeover time at 110 % Uc
  ms  
Changeover time min.
  ms 40
Changeover time max.
  ms 50
Arcing time at 690 V AC
  ms max. 12
Auxiliary contacts
Positive operating contacts to ZH 1/457, including auxiliary contact module
    Yes
Rated impulse withstand voltage
Uimp V AC 6000
Rated insulation voltage
Ui V AC 690
Rated operational voltage
Ue V  
Rated operational voltage
Ue V AC 600
Safe isolation to VDE 0106 Part 101 and Part 101/A1
     
between coil and auxiliary contacts
  V AC 300
between the auxiliary contacts
  V AC 300
Rated operational current
Ie A  
AC-15
     
220/240 V
Ie A 6
380/415 V
Ie A 3
500 V
Ie A 1.5
DC-13
     
Contacts in series:
  A  
1
24 V A 2.5
2
60 V A 2.5
3
100 V A 1.5
3
220 V A 0.5
Control circuit reliability (at Ue= 24 V DC, Umin= 17 V, I min= 5.4 mA)
Failure rate λ <10-8, < one failure at 100 million operations
Component lifespan at Ue= 240 V
     
AC-15
Operations x 106 0.2
DC-13
     
L/R = 50 ms: 2 contacts in series at Ie= 0.5 A
Operations x 106 0.15
Notes
    Switch-on and switch-off conditions based on DC-13, time constant as specified
Short-circuit rating without welding
     
Maximum overcurrent protective device
     
Short-circuit protection only
    PKZM0-4
Short-circuit protection maximum fuse
     
500 V
  A gG/gL 6
500 V
  A fast 10
Current heat loss at Ith
     
Per contact
  W 0.3
Technical data according to ETIM 4.0
Number of main contacts as N/Os
    3
Rated operation current Ie at AC-1, 400 V
    22
Connection type main circuit
    Screw connection
Rated control voltage Us at AC 60HZ
  V 0
Number of auxiliary contacts as N/Os
    1
Rated control voltage Us at AC 50HZ
  V 0
Number of auxiliary contacts as N/Cs
    0
Suitable for rail-mounting
    No
Rated control voltage Us at DC
  V 24
Voltage type for actuation
    DC
Rated operation current Ie at AC-3, 400 V
  A 9
Number of N/Cs as main contact
    0
Motor rating at AC-3, 400 V
  kWh 4
Characteristics
1: Overload relay
2: Suppressor
3: Auxiliary contact modules
Enclosure totally insulated
Squirrel-cage motor
Operating characteristics
Starting:from rest
Stopping:after attaining full running speed
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 1 x rated motor current
Utilization category
100 % AC-3
Typical applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
Fans
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevators
Air conditioning system
General drives in manufacturing and processing machines
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
Switching duty for non-motor loads, 3-pole, 4-pole
Operating characteristics
Non-inductive or slightly inductive loads
Electrical characteristics
Make: 1 x rated current
Break: 1 x rated current
Utilization category
100 % AC-1
Typical applications
Electric heat
Short-time loading, 3-pole
Time interval between two loading cycles: 15 minutes
Dimensions