Moduł styków pomocniczych 4Z ;mont.centralnie 40DILE

  • szt.
  • Cena brutto: 102,64 zł 83,45 zł
Moduł styków pomocniczych 4Z ;mont.centralnie 40DILE
Program
Product range
  Accessories
Description
  with interlocked opposing contacts
Pole
  4 pole
Connection technique
  Screw terminals
Contacts
   
N/O = Normally open
  4 N/O
AC-15
   
AC-15
   
220 V 230 V 240 V
IeA4
380 V

400 V

415 V
IeA2
Conv. thermal current
IthA10
Code number and version of combination
   
DILER-40(-G)
  80E
DILER-31(-G)
  71
DILER-22(-G)
  62
Contact sequence
  
Can be combined with contactor
  DILEM-10(-G)(…)
DILEM-01(-G)(…)
DILEM-4(-G)(…)
DILER40(-G)
DILER31(-G)
DILER22
DILEEM-10(-G)(…)
DILEEM-01(-G)(…)
DILEM12-10(-G)(…)
DILEM12-01(-G)(…)
InstructionsContacts to EN 50005
Contacts according to EN 50012 are to be prefered.
Version E combinations correspond to EN 50011 and are to be preferred.
InstructionsNo interlocked opposing mechanism in NO early-makes and NC late-breaks.
Auxiliary contact modules with positive acting contacts
Approbationen
Product StandardsIEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.E29184
UL CCNNKCR
CSA File No.012528
CSA Class No.3211-03
NA CertificationUL Listed, CSA certified
 
Auxiliary contacts
flexible with ferrule
  Yes
Rated impulse withstand voltage
UimpV AC6000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV AC600
Safe isolation to VDE 0106 Part 101 and Part 101/A1
   
between coil and auxiliary contacts
 V AC300
between the auxiliary contacts
 V AC300
Rated operational current
IeA 
AC-15
   
220/240 V
IeA4
60 Hz
IeA2
500 V
IeA1.5
DC L/R 15 ms
   
Contacts in series:
 A 
1
24 VA2.5
2
60 VA2.5
3
100 VA1.5
3
220 VA0.5
Conv. thermal current
IthA10
Control circuit reliability (at Ue= 24 V DC, Umin= 17 V, I min= 5.4 mA)
Failure rateλ<10-8, < one failure at 100 million operations
Component lifespan at Ue= 240 V
   
AC-15
Operationsx 1060.2
DC
   
Footnote
  Switch-on and switch-off conditions based on DC-13, time constant as specified
L/R = 50 ms: 2 contacts in series at Ie= 0.5 A
Operationsx 1060.15
Short-circuit rating without welding
   
Maximum overcurrent protective device
   
Short-circuit protection only
  PKZM0-4
Short-circuit protection maximum fuse
   
500 V
 A gG/gL6
500 V
 A fast10
Current heat loss at Ith
   
Per contact
 W0.2
Technical data according to ETIM 4.0
Suitable for earth leakage circuit breaker
  No
Type of electric connection
  Screw connection
Rated operation current Ie at AC-15, 230 V
 A4
Mounting type
  Front mount
Suitable for pendant switch
  No
Suitable for front element
  No
Suitable for circuit-breakers
  No
Suitable for safety position switches
  No
Suitable for step switches
  No
Suitable for pressure switch/selector switch actuator
  No
Suitable for cam switches
  No
Suitable for motor protective circuit breakers
  No
Suitable for series-mounting relays
  No
Suitable for solenoid
  No
Suitable for compact switch-disconnector
  No
Suitable for miniature circuit-breakers
  No
Suitable for pulse relay
  No
Suitable for contactor relay relay
  YES
Suitable for pendant pushbutton
  No
Suitable for residual current device
  No
Number of contacts as change-over contact
  0
Number of contacts as N/O
  4
Number of contacts as NC
  0
Suitable for impulse relays
  No
Suitable for position switches
  No
Suitable for switch-disconnector/residual current device
  No
Suitable for contactors
  YES
Suitable for installation contactor / installation relay
  YES
Characteristics
Switching duty for non-motor loads, 3-pole, 4-pole
Operating characteristics
Non-inductive or slightly inductive loads
Electrical characteristics
Make: 1 x rated current
Break: 1 x rated current
Utilization category
100 % AC-1
Typical applications
Electric heat
Short-time loading, 3-pole
Time interval between two loading cycles: 15 minutes

Opis pochodzi ze strony www.moeller.net .