Rozszerzenie przekaźnika programowalnego EASY618-DC-RE
Program
Product range | Control relays easyRelay Multi-function-display MFD-Titan | ||
Subrange | I/O expansions digital | ||
Basic function | Expansions | ||
Can be used through easyLink | |||
Inputs | |||
Inputs expansion (number) | digital: 12 | ||
Outputs | |||
Type | Relay | ||
Supply voltage | 24 V DC | ||
For use with | easy700 easy800 EC4P MFD-CP8… | ||
Accessories | I/O expansions digital | ||
Description | Can be used through easyLink | ||
Inputs | |||
Digital | 12 | ||
Outputs | |||
Relay 10 A (UL) | 6 | ||
Information relevant for export to North America Product StandardsIEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No.E29184 UL CCNNKCR CSA File No.012528 CSA Class No.3211-03 NA CertificationUL Listed, CSA certified |
Approbationen
|
General | |||
Standards | EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27 | ||
Dimensions (W x H x D) | mm | 107.5 x 90 x 58 (6 PE) | |
Weight | kg | 0.3 | |
Mounting | Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) | ||
Terminal capacities | |||
Solid | mm2 | 0.2/2.5 (AWG 22 - 12) | |
Flexible with ferrule | mm2 | 0.2/2.5 (AWG 22 - 12) | |
Standard screwdriver | mm | 3.5 x 0.8 | |
Max. tightening torque | Nm | 0.6 | |
Climatic environmental conditions | |||
Operating ambient temperature | °C | -25 … 55, low temperatures to IEC 60068-2-1, high temperatures to IEC 60068-2-2 | |
Condensation | Take appropriate measures to prevent condensation | ||
LCD display (clearly legible) | °C | 0- 55 | |
Storage | °C | -40 - +70 | |
Relative humidity, non-condensing (IEC/EN 60068-2-30) | % | 5- 95 | |
Air pressure (operation) | hPa | 795- 1080 | |
Corrosion resistance | cm³/m³ | ||
IEC/EN 60068-2-42 | 4 days SO2 | cm3/m3 | 10 |
IEC/EN 60068-2-43 | 4 days H2S | cm3/m3 | 1 |
Ambient conditions, mechanical | |||
Protection type (IEC/EN 60529, EN50178, VBG 4) | IP20 | ||
Vibrations (IEC/EN 60068-2-6) | Hz | ||
constant amplitude | Hz | 10 - 57 (0.15 mm) | |
constant acceleration | Hz | 57 - 150 (2g) | |
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms | Impacts | 18 | |
Drop to IEC/EN 60068-2-31 | Drop height | mm | 50 |
Free fall, packaged (IEC/EN 60068-2-32) | m | 1 | |
Mounting position | Vertical or horizontal | ||
Electromagnetic compatibility (EMC) | |||
Overvoltage category/pollution degree | II/2 | ||
Electrostatic discharge (ESD) | |||
Air discharge | kV | 8 | |
Contact discharge | kV | 6 | |
Electromagnetic fields (RFI), to IEC EN 61000-4-2 | V/m | 10 | |
Radio interference suppression | EN 55011 Class B, EN 55022 Class B | ||
Burst | |||
according to IEC/EN 61000-4-4 | |||
Supply cables | kV | 2 | |
Signal lines | kV | 2 | |
power pulses (Surge) | according to IEC/EN 61000-4-5 2 kV (supply cables, symmetrical, EASY...AC) 0.5 kV (supply cables, symmetrical, easy-DC) | ||
Radiated RFI (IEC/EN 61000-4-6) | V | 10 | |
Insulation resistance | |||
Clearance in air and creepage distances | EN 50178, UL 508, CSA C22.2, No. 142 | ||
Insulation resistance | EN 50178 | ||
Power supply | |||
Rated operational voltage | Ue | V | 24 DC (-15/+20%) |
Permissible range | 20.4 - 28.8 V DC | ||
Residual ripple | % | 5 | |
Input current | typ. 140 mA at rated operating voltage | ||
Voltage dips | ms | ≤10 | |
Heat dissipation | Normally3.4 W | ||
Digital inputs | |||
Number | 12 | ||
Status indication | LCD-display (if present) | ||
Potential isolation | from the outputs | ||
Supply voltage | 24 V DC | ||
Rated operational voltage | Ue | < 5 V DC (I1 - I12, R1 - R12) at signal "0" | |
Input current at signal "1" | mA | 3.3 (at 24 V DC) R1 to R6 (R12) | |
Deceleration time | ms | 20 (from “0” to “1”, debounce ON) Normally 0.25 (R1 - R12) (from “0” to “1”, debounce OFF) 20 (from “1” to “0”, debounce ON) | |
Cable length | m | 100 (unshielded) | |
Relay outputs | |||
Number | 6 | ||
Outputs in groups of | 1 | ||
Parallel switching of outputs for increased output | Not permissible | ||
Protection of an output relay | Miniature circuit-breaker B16 or fuse 8 A (slow) | ||
Lifespan, mechanical | Operations | x 106 | 10 |
Contacts | |||
Conventional thermal current (10 A UL) | A | 8 | |
Recommended for load: 12 V AC/DC | mA | > 500 | |
Short-circuit-proof cos ϕ = 1, characteristic B16 at 600 A | A | 16 | |
Short-circuit-proof cos ϕ = 0.5 to 0.7, characteristic B16 at 900 A | A | 16 | |
Rated impulse withstand voltage Uimpof contact coil | kV | 6 | |
Rated operational voltage | Ue | V AC | 250 |
Rated insulation voltage | Ui | V AC | 250 |
Safe isolation according to EN 50178 | V AC | 300 between coil and contact 300 between two contacts | |
Making capacity | |||
AC-15, 230 V AC, 3 A | Operations | 300000 | |
DC-13, 24 V DC, 5 A, 0.1 Hz | Operations | 200000 | |
Breaking capacity | |||
AC-15, 250 V AC, 3 A (600 Ops./h) | Operations | 300000 | |
DC-13 L/R 150 ms 24 V DC, 1 A (500 Ops./h) | Operations | 200000 | |
Filament bulb load | |||
1000 W at 230/240 V AC | Operations | 25000 | |
500 W at 115/120 V AC | Operations | 25000 | |
Fluorescent lamp load | |||
Fluorescent lamp load 10 x 58 W at 230/240 V AC | |||
With upstream electrical device | Operations | 25000 | |
Uncompensated | Operations | 25000 | |
Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated | Operations | 25000 | |
Switching frequency | |||
Mechanical operations | x 106 | 10 | |
Switching frequency | Hz | 10 | |
Resistive load/lamp load | Hz | 2 | |
Inductive load | Hz | 0.5 | |
UL/CSA | |||
Uninterrupted current at 240 V AC | A | 10 | |
Uninterrupted current at 24 V DC | A | 8 | |
AC | |||
Control Circuit Rating Codes (utilization category) | B 300 Light Pilot Duty | ||
Max. rated operational voltage | V AC | 300 | |
Max. thermal uninterrupted current at B 300(RefExtrakt) | A | 5 | |
Max. make/break capacity at B 300 | VA | 3600/360 | |
DC | |||
Control Circuit Rating Codes (utilization category) | R 300 Light Pilot Duty | ||
Max. rated operational voltage | V DC | 300 | |
Max. thermal uninterrupted current at R 300 | A | 1 | |
Max. make/break capacity at R 300 | VA | 28/28 |
Technical data according to ETIM 4.0
Voltage type of supply voltage | DC | ||
Expandable | YES | ||
With display | YES | ||
Number of HW-interfaces RS232 | 0 | ||
Number of HW-interfaces serial TTY | 0 | ||
Max. number of integrated digital inputs | 12 | ||
Supporting protocol for LON | No | ||
With time switch | No | ||
Max. number of integrated analog outputs | 0 | ||
Number of HW-interfaces RS485 | 0 | ||
Max. number of integrated digital outputs | 6 | ||
Protection type (IP) | IP20 | ||
Height | mm | 90 | |
Width | mm | 108 | |
Number of Industrial Ethernet HW interfaces | 0 | ||
Number of HW-interfaces RS422 | 0 | ||
Depth | mm | 60 | |
Switching current | A | 8 | |
Max. number of integrated analog inputs | 0 | ||
With relay output | YES | ||
Number of HW-interfaces other | 0 |