Rozszerzenie przekaźnika programowalnego EASY618-DC-RE
Program
Product range
  Control relays easyRelay
Multi-function-display MFD-Titan
Subrange
  I/O expansions digital
Basic function
  Expansions
 
  Can be used through easyLink
Inputs
   
Inputs expansion (number)
  digital: 12
Outputs
   
Type
  Relay
Supply voltage
  24 V DC
For use with
  easy700
easy800
EC4P
MFD-CP8…
Accessories
  I/O expansions digital
Description
  Can be used through easyLink
Inputs
   
Digital
  12
Outputs
   
Relay 10 A (UL)
  6
Information relevant for export to North America

Product StandardsIEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking

UL File No.E29184

UL CCNNKCR

CSA File No.012528

CSA Class No.3211-03

NA CertificationUL Listed, CSA certified

Approbationen
Product StandardsIEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking
UL File No.E135462
UL CCNNRAQ, NRAQ7
CSA File No.012528
CSA Class No.2252-01
NA CertificationUL Listed, CSA certified
Degree of ProtectionIEC: IP20, UL/CSA Type: -
 
General
Standards
  EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27
Dimensions (W x H x D)
 mm107.5 x 90 x 58 (6 PE)
Weight
 kg0.3
Mounting
  Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Terminal capacities
Solid
 mm20.2/2.5 (AWG 22 - 12)
Flexible with ferrule
 mm20.2/2.5 (AWG 22 - 12)
Standard screwdriver
 mm3.5 x 0.8
Max. tightening torque
 Nm0.6
Climatic environmental conditions
Operating ambient temperature
 °C-25 … 55, low temperatures to IEC 60068-2-1, high temperatures to IEC 60068-2-2
Condensation
  Take appropriate measures to prevent condensation
LCD display (clearly legible)
 °C0- 55
Storage
 °C-40 - +70
Relative humidity, non-condensing (IEC/EN 60068-2-30)
 %5- 95
Air pressure (operation)
 hPa795- 1080
Corrosion resistance
 cm³/m³ 
IEC/EN 60068-2-42
4 days SO2cm3/m310
IEC/EN 60068-2-43
4 days H2Scm3/m31
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
  IP20
Vibrations (IEC/EN 60068-2-6)
 Hz 
constant amplitude
 Hz10 - 57 (0.15 mm)
constant acceleration
 Hz57 - 150 (2g)
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms
 Impacts18
Drop to IEC/EN 60068-2-31
Drop heightmm50
Free fall, packaged (IEC/EN 60068-2-32)
 m1
Mounting position
  Vertical or horizontal
Electromagnetic compatibility (EMC)
Overvoltage category/pollution degree
  II/2
Electrostatic discharge (ESD)
   
Air discharge
 kV8
Contact discharge
 kV6
Electromagnetic fields (RFI), to IEC EN 61000-4-2
 V/m10
Radio interference suppression
  EN 55011 Class B, EN 55022 Class B
Burst
   
 
  according to IEC/EN 61000-4-4
Supply cables
 kV2
Signal lines
 kV2
power pulses (Surge)
  according to IEC/EN 61000-4-5
2 kV (supply cables, symmetrical, EASY...AC)
0.5 kV (supply cables, symmetrical, easy-DC)
Radiated RFI (IEC/EN 61000-4-6)
 V10
Insulation resistance
Clearance in air and creepage distances
  EN 50178, UL 508, CSA C22.2, No. 142
Insulation resistance
  EN 50178
Power supply
Rated operational voltage
UeV24 DC (-15/+20%)
Permissible range
  20.4 - 28.8 V DC
Residual ripple
 %5
Input current
  typ. 140 mA at rated operating voltage
Voltage dips
 ms≤10
Heat dissipation
  Normally3.4 W
Digital inputs
Number
  12
Status indication
  LCD-display (if present)
Potential isolation
  from the outputs
Supply voltage
  24 V DC
Rated operational voltage
Ue < 5 V DC (I1 - I12, R1 - R12) at signal "0"
Input current at signal "1"
 mA3.3 (at 24 V DC) R1 to R6 (R12)
Deceleration time
 ms20 (from “0” to “1”, debounce ON)
Normally 0.25 (R1 - R12) (from “0” to “1”, debounce OFF)
20 (from “1” to “0”, debounce ON)
Cable length
 m100 (unshielded)
Relay outputs
Number
  6
Outputs in groups of
  1
Parallel switching of outputs for increased output
  Not permissible
Protection of an output relay
  Miniature circuit-breaker B16 or fuse 8 A (slow)
Lifespan, mechanical
Operationsx 10610
Contacts
   
Conventional thermal current (10 A UL)
 A8
Recommended for load: 12 V AC/DC
 mA> 500
Short-circuit-proof cos ϕ = 1, characteristic B16 at 600 A
 A16
Short-circuit-proof cos ϕ = 0.5 to 0.7, characteristic B16 at 900 A
 A16
Rated impulse withstand voltage Uimpof contact coil
 kV6
Rated operational voltage
UeV AC250
Rated insulation voltage
UiV AC250
Safe isolation according to EN 50178
 V AC300 between coil and contact
300 between two contacts
Making capacity
   
AC-15, 230 V AC, 3 A
Operations 300000
DC-13, 24 V DC, 5 A, 0.1 Hz
Operations 200000
Breaking capacity
   
AC-15, 250 V AC, 3 A (600 Ops./h)
Operations 300000
DC-13 L/R 150 ms 24 V DC, 1 A (500 Ops./h)
Operations 200000
Filament bulb load
   
1000 W at 230/240 V AC
Operations 25000
500 W at 115/120 V AC
Operations 25000
Fluorescent lamp load
   
Fluorescent lamp load 10 x 58 W at 230/240 V AC
   
With upstream electrical device
Operations 25000
Uncompensated
Operations 25000
Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated
Operations 25000
Switching frequency
   
Mechanical operations
 x 10610
Switching frequency
 Hz10
Resistive load/lamp load
 Hz2
Inductive load
 Hz0.5
UL/CSA
   
Uninterrupted current at 240 V AC
 A10
Uninterrupted current at 24 V DC
 A8
AC
   
Control Circuit Rating Codes (utilization category)
  B 300 Light Pilot Duty
Max. rated operational voltage
 V AC300
Max. thermal uninterrupted current at B 300(RefExtrakt)
 A5
Max. make/break capacity at B 300
 VA3600/360
DC
   
Control Circuit Rating Codes (utilization category)
  R 300 Light Pilot Duty
Max. rated operational voltage
 V DC300
Max. thermal uninterrupted current at R 300
 A1
Max. make/break capacity at R 300
 VA28/28
Technical data according to ETIM 4.0
Voltage type of supply voltage
  DC
Expandable
  YES
With display
  YES
Number of HW-interfaces RS232
  0
Number of HW-interfaces serial TTY
  0
Max. number of integrated digital inputs
  12
Supporting protocol for LON
  No
With time switch
  No
Max. number of integrated analog outputs
  0
Number of HW-interfaces RS485
  0
Max. number of integrated digital outputs
  6
Protection type (IP)
  IP20
Height
 mm90
Width
 mm108
Number of Industrial Ethernet HW interfaces
  0
Number of HW-interfaces RS422
  0
Depth
 mm60
Switching current
 A8
Max. number of integrated analog inputs
  0
With relay output
  YES
Number of HW-interfaces other
  0
Dimensions
6

Opis pochodzi ze strony www.moeller.net .