M22-CKC10 - Element stykowy 1Z moc tył, zac spręż
- szt.
- Rabat: -9,36 zł (40 %)
- (Rabat brutto: -11,51 zł (40 %))
- Cena brutto: 17,27 zł / szt. 14,04 zł / szt.
Element stykowy 1Z montowany do dna M22-CKC10
Program
Approbationen
|
General | |||
Standards | IEC/EN 60947 VDE 0660 | ||
Lifespan, mechanical | Operations | x 106 | > 5 |
Operating frequency | Operations/h | 3600 | |
Actuating force | n | 5 | |
Operating torque (screw terminals) | Nm | 0.8 | |
Protection type | IP20 | ||
Climatic proofing | Damp heat, constant to IEC 60068-2-78 Damp heat, cyclic to IEC 60068-2-30 | ||
Ambient temperature | °C | ||
Open | °C | -25- +70 | |
Mounting position | As required | ||
Mechanical shock resistance | g | 30 Shock duration 11 ms Sinusoidal according to IEC 60068-2-27 | |
Terminal capacities | mm2 | ||
Solid | mm2 | 0.75 - 2.5 | |
Stranded | mm2 | 0.5 - 2.5 | |
Contacts | |||
Rated impulse withstand voltage | Uimp | V AC | 6000 |
Rated insulation voltage | Ui | V | 500 |
Overvoltage category/pollution degree | III/3 | ||
Control circuit reliability | |||
at 24 V DC/5 mA | HF | Fault probability | < 10-7(i.e. 1 failure to 107operations) |
at 5 V DC/1 mA | HF | Fault probability | < 5 x 10-6(i.e. 1 failure in 5 x 106operations) |
Max. short-circuit protective device | |||
Fuseless | Type | PKZM0-10/FAZ-B6/1 | |
Fuse | gG/gL | A | 10 |
Switching capacity | |||
Rated operational current | Ie | A | |
AC-15 | |||
115 V | Ie | A | 6 |
230 V | Ie | A | 6 |
400 V | Ie | A | 4 |
500 V | Ie | A | 2 |
DC-13 | |||
24 V | Ie | A | 3 |
42 V | Ie | A | 1.7 |
60 V | Ie | A | 1.2 |
110 V | Ie | A | 0.8 |
220 V | Ie | A | 0.3 |
Lifespan, electrical | |||
AC-15 | |||
230 V/0.5 A | Operations | x 106 | 1.6 |
230 V/1.0 A | Operations | x 106 | 1 |
230 V/3.0 A | Operations | x 106 | 0.7 |
DV-13 | |||
12 V/2.8 A | Operations | x 106 | 1.2 |
Indoor and protected outdoor installation |
Technical data according to ETIM 4.0
Suitable for earth leakage circuit breaker | No | ||
Type of electric connection | Spring clamp connection | ||
Rated operation current Ie at AC-15, 230 V | A | 6 | |
Mounting type | Base fixing | ||
Suitable for pendant switch | No | ||
Suitable for front element | YES | ||
Suitable for circuit-breakers | No | ||
Suitable for safety position switches | No | ||
Suitable for step switches | No | ||
Suitable for pressure switch/selector switch actuator | YES | ||
Suitable for cam switches | No | ||
Suitable for motor protective circuit breakers | No | ||
Suitable for series-mounting relays | No | ||
Suitable for solenoid | No | ||
Suitable for compact switch-disconnector | No | ||
Suitable for miniature circuit-breakers | No | ||
Suitable for pulse relay | No | ||
Suitable for contactor relay relay | No | ||
Suitable for pendant pushbutton | No | ||
Suitable for residual current device | No | ||
Number of contacts as change-over contact | 0 | ||
Number of contacts as N/O | 1 | ||
Number of contacts as NC | 0 | ||
Suitable for impulse relays | No | ||
Suitable for position switches | No | ||
Suitable for switch-disconnector/residual current device | No | ||
Suitable for contactors | No | ||
Suitable for installation contactor / installation relay | No |
CAD-Data
|
Opis pochodzi ze strony www.moeller.net .