M22-CKC10 - Element stykowy 1Z moc tył, zac spręż

  • szt.
  • Rabat: -9,36 zł (40 %)
  • (Rabat brutto: -11,51 zł (40 %))
  • Cena brutto: 17,27 zł / szt. 14,04 zł / szt.
Element stykowy 1Z montowany do dna M22-CKC10
Program
Range
  RMQ-Titan (drilling dimensions 22.5 mm)
Basic function
  Accessories
Single unit/Complete unit
  Element
Connection technique
  Cage Clamp
Fixing
  Base fixing
Auxiliary contacts: = safety function, by positive opening to IEC/EN 60947-5-1
   
N/O = Normally open
  1 N/O
Contact sequence
  
Contact travel diagram, stroke in connection with front element
  
Configuration
  
Protection type
  IP20
Connection to SmartWire-DT
  no
Approbationen
Product StandardsIEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
UL File No.E29184
UL CCNNKCR
CSA File No.012528
CSA Class No.3211-03
NA CertificationUL Listed, CSA certified
Degree of ProtectionUL/CSA Type: -
 
General
Standards
  IEC/EN 60947
VDE 0660
Lifespan, mechanical
Operationsx 106> 5
Operating frequency
Operations/h 3600
Actuating force
 n5
Operating torque (screw terminals)
 Nm0.8
Protection type
  IP20
Climatic proofing
  Damp heat, constant to IEC 60068-2-78
Damp heat, cyclic to IEC 60068-2-30
Ambient temperature
 °C 
Open
 °C-25- +70
Mounting position
  As required
Mechanical shock resistance
 g30
Shock duration 11 ms
Sinusoidal
according to IEC 60068-2-27
Terminal capacities
 mm2 
Solid
 mm20.75 - 2.5
Stranded
 mm20.5 - 2.5
Contacts
Rated impulse withstand voltage
UimpV AC6000
Rated insulation voltage
UiV 500
Overvoltage category/pollution degree
  III/3
Control circuit reliability
   
at 24 V DC/5 mA
HFFault probability< 10-7(i.e. 1 failure to 107operations)
at 5 V DC/1 mA
HFFault probability < 5 x 10-6(i.e. 1 failure in 5 x 106operations)
Max. short-circuit protective device
   
Fuseless
 TypePKZM0-10/FAZ-B6/1
Fuse
gG/gLA10
Switching capacity
Rated operational current
IeA 
AC-15
   
115 V
IeA6
230 V
IeA6
400 V
IeA4
500 V
IeA2
DC-13
   
24 V
IeA3
42 V
IeA1.7
60 V
IeA1.2
110 V
IeA0.8
220 V
IeA0.3
Lifespan, electrical
   
AC-15
   
230 V/0.5 A
Operationsx 1061.6
230 V/1.0 A
Operationsx 1061
230 V/3.0 A
Operationsx 1060.7
DV-13
   
12 V/2.8 A
Operationsx 1061.2

Indoor and protected outdoor installation

Technical data according to ETIM 4.0
Suitable for earth leakage circuit breaker
  No
Type of electric connection
  Spring clamp connection
Rated operation current Ie at AC-15, 230 V
 A6
Mounting type
  Base fixing
Suitable for pendant switch
  No
Suitable for front element
  YES
Suitable for circuit-breakers
  No
Suitable for safety position switches
  No
Suitable for step switches
  No
Suitable for pressure switch/selector switch actuator
  YES
Suitable for cam switches
  No
Suitable for motor protective circuit breakers
  No
Suitable for series-mounting relays
  No
Suitable for solenoid
  No
Suitable for compact switch-disconnector
  No
Suitable for miniature circuit-breakers
  No
Suitable for pulse relay
  No
Suitable for contactor relay relay
  No
Suitable for pendant pushbutton
  No
Suitable for residual current device
  No
Number of contacts as change-over contact
  0
Number of contacts as N/O
  1
Number of contacts as NC
  0
Suitable for impulse relays
  No
Suitable for position switches
  No
Suitable for switch-disconnector/residual current device
  No
Suitable for contactors
  No
Suitable for installation contactor / installation relay
  No
Dimensions
Pushbutton with M22-(C)K…
Pushbutton with M22-(C) LED… + M22-XLED…

Opis pochodzi ze strony www.moeller.net .